Winding short-circuit and open-circuit testing for DC motors

Shorted turns show up as unbalanced current and local overheating, open circuits as lost torque or a dead machine. Finding the exact coil needs a method, and the resistance comparison plus bar-to-bar drop test locate nearly every fault.

1. How it works

Interturn shorts in a field winding raise the field current while reducing flux, so speed climbs at the same load and the coil runs hot. Armature shorts bring hard starting, heavy sparking and blackened bars. Quantify with a double bridge: a field coil reading 5 percent below its peers has shorted turns, remembering that 10C of temperature difference shifts resistance 4 percent. For the armature, measure resistance between adjacent commutator bars; healthy pairs match within 10 percent, a low pair means a short and a high pair an open or a bad joint.

2. Practice and pitfalls

Confirm with the drop test: feed the armature a low DC voltage giving about 10 percent of rated current and read the millivolt drop across each adjacent bar pair. Abnormally high drop marks an open circuit or dry joint, zero drop marks a short. The field sequence is look first, then measure: inspect bar burning and winding discoloration, test insulation to rule out earth faults, then compare winding resistances with history, and finish suspect coils with a surge test. Grip the armature during the drop test so it cannot spin and whip the leads.

3. Test methods for DC motor winding faults

Fault typeTypical signsMethodCriterion
field interturn shorthigh field current, high speedbridge resistance per coil5% below similar coils
armature shorthard start, sparks, black barsbar resistance or drop testlow pair or zero drop
field openshunt machine dead, zero field currentcontinuity or bridgeinfinite resistance
armature opentorque pulsation, explosive sparksbar resistance sweepopen pair located
dry jointintermittent sparksdrop test recheckabnormally high drop
insulation degradationsmell, discoloration, hot spotIR scan plus surge testsurge breakdown

4. Notes

Never skip the order: insulation first, then resistance, then drop test, or an earth fault gets misread as interturn trouble. Build the resistance archive on first contact with any machine.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1311 (DC machine test methods) for winding tests; ratings per GB/T 755 (IEC 60034-1). Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Drop test with the armature free to rotate: energized windings spin the armature, whipping leads and endangering the operator
② Judging interturn shorts from raw resistance: a 10C temperature bias shifts 4 percent and every comparison is wrong without correction
③ Smearing varnish over an unfound short: the fault keeps developing and burns through to earth within hours, turning a coil repair into a rewind

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.