Shorted turns show up as unbalanced current and local overheating, open circuits as lost torque or a dead machine. Finding the exact coil needs a method, and the resistance comparison plus bar-to-bar drop test locate nearly every fault.
Interturn shorts in a field winding raise the field current while reducing flux, so speed climbs at the same load and the coil runs hot. Armature shorts bring hard starting, heavy sparking and blackened bars. Quantify with a double bridge: a field coil reading 5 percent below its peers has shorted turns, remembering that 10C of temperature difference shifts resistance 4 percent. For the armature, measure resistance between adjacent commutator bars; healthy pairs match within 10 percent, a low pair means a short and a high pair an open or a bad joint.
Confirm with the drop test: feed the armature a low DC voltage giving about 10 percent of rated current and read the millivolt drop across each adjacent bar pair. Abnormally high drop marks an open circuit or dry joint, zero drop marks a short. The field sequence is look first, then measure: inspect bar burning and winding discoloration, test insulation to rule out earth faults, then compare winding resistances with history, and finish suspect coils with a surge test. Grip the armature during the drop test so it cannot spin and whip the leads.
| Fault type | Typical signs | Method | Criterion |
|---|---|---|---|
| field interturn short | high field current, high speed | bridge resistance per coil | 5% below similar coils |
| armature short | hard start, sparks, black bars | bar resistance or drop test | low pair or zero drop |
| field open | shunt machine dead, zero field current | continuity or bridge | infinite resistance |
| armature open | torque pulsation, explosive sparks | bar resistance sweep | open pair located |
| dry joint | intermittent sparks | drop test recheck | abnormally high drop |
| insulation degradation | smell, discoloration, hot spot | IR scan plus surge test | surge breakdown |
Never skip the order: insulation first, then resistance, then drop test, or an earth fault gets misread as interturn trouble. Build the resistance archive on first contact with any machine.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1311 (DC machine test methods) for winding tests; ratings per GB/T 755 (IEC 60034-1). Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.