Aluminium electrolytics degrade on the shelf: oxide thins, leakage grows - re-form before use.
Re-form through a series resistor: 0.3Un/1h → 0.6Un/1h → 1.0Un/2~4h, monitoring leakage; cull failures.
Tantalums need current-limited first power-up; prefer FIFO stock control for electrolytics.
| Type | Sensitivity | After 2 years | Cull criteria |
|---|---|---|---|
| Al electrolytic | High | Re-form | Leak/C/ESR |
| Solid polymer | Medium | Direct use | ESR & visual |
| Tantalum | High (surge) | Current-limited | Leakage |
| Film | Low | Routine test | C & voltage |
| Ceramic | Low | Routine test | C & visual |
| Supercap | Medium | Leak test | Leak & C |
Apply the points above to Capacitor aging after long storage and re; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per IEC 60384-4 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.