First-order transients and the three-element method

f(t)=f(∞)+[f(0+)−f(∞)]e−t/τ - initial value, final value and τ define everything.

1. How it works

f(0+): capacitor voltage and inductor current are continuous; f(∞): C open, L short; τ=ReqC or L/Req with independent sources zeroed.

2. Practice and pitfalls

Worked case: 12V, R=2k, C=100μF from 4V → UC(t)=12−8e−t/0.2; at 0.2s, 9.06V.

3. Three-element quick table

ElementHowC circuitL circuit
InitialContinuityUC continuousIL continuous
FinalNew steadyC openL short
τReqC / L/Req——
ResponseThree-element formula——
ReqSources zeroedV-source shortI-source open
Checkt=0 & t=∞Both matchBoth match

4. Notes

Apply the points above to First; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 3102.5 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Allowing a jump in UC or IL
② Forgetting to zero the sources for Req
③ Applying the method to second-order circuits

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.