Inrush current of a rectifier and how to limit it

At switch on the filter capacitor looks like a short, so the bridge can see ten to几十 times rated current as inrush. This page explains where inrush comes from and gives NTC and soft start fixes.

1. How it works

Because capacitor voltage cannot jump, at power on the cap is at 0 V and the mains dumps current through the bridge, peaking at tens of times rated for a few to tens of milliseconds. The surge flows through the bridge and cap ESR, overheating both. Small supplies survive, but a kilowatt supply with large capacitance can hit hundreds of amperes and must be tamed.

2. Practice and pitfalls

One fix is an NTC thermistor in series: cold resistance is high, limiting inrush, then it warms and drops, so steady loss is small. The catch is that switching on again while still hot leaves low resistance and loses limiting; a bypass relay after start solves both loss and the hot state.

3. Inrush limiting options

MethodProsCons
NTCsimple, cheapfails when hot
Series Rrepeatableneeds bypass
Soft start ICsmoothcostlier
Bypass relayno steady losscan stick
Current Rcheappower enough
Ramp dutysmoothestneeds control

4. Notes

Use NTC for low power but add a bypass relay for hot restarts; for big supplies a series resistor with relay soft start is steadiest. Rate every limiter by inrush energy with margin and account for repeated switching heat.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Inrush and turn on per GB/T 5226.1; module test to IEC 62310 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① NTC too small fails to limit and the bridge still takes tens of times current.
② Switching on again while the NTC is hot loses limiting; add a bypass relay.
③ Rating the limiter resistor by steady power lets inrush energy blow it; rate by energy.