At switch on the filter capacitor looks like a short, so the bridge can see ten to几十 times rated current as inrush. This page explains where inrush comes from and gives NTC and soft start fixes.
Because capacitor voltage cannot jump, at power on the cap is at 0 V and the mains dumps current through the bridge, peaking at tens of times rated for a few to tens of milliseconds. The surge flows through the bridge and cap ESR, overheating both. Small supplies survive, but a kilowatt supply with large capacitance can hit hundreds of amperes and must be tamed.
One fix is an NTC thermistor in series: cold resistance is high, limiting inrush, then it warms and drops, so steady loss is small. The catch is that switching on again while still hot leaves low resistance and loses limiting; a bypass relay after start solves both loss and the hot state.
| Method | Pros | Cons |
|---|---|---|
| NTC | simple, cheap | fails when hot |
| Series R | repeatable | needs bypass |
| Soft start IC | smooth | costlier |
| Bypass relay | no steady loss | can stick |
| Current R | cheap | power enough |
| Ramp duty | smoothest | needs control |
Use NTC for low power but add a bypass relay for hot restarts; for big supplies a series resistor with relay soft start is steadiest. Rate every limiter by inrush energy with margin and account for repeated switching heat.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Inrush and turn on per GB/T 5226.1; module test to IEC 62310 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.