Mechanical inertia and motor start time calculation

How long for a motor to accelerate from rest to working speed is set by mechanical inertia and available acceleration torque. Wrong start time ruins line cycle and motor selection. This page gives inertia and start time calculation.

1. How it works

Mechanical system inertia J in kg m2 quantifies rotational inertia and linear mass m also reflects to the shaft by J_eq equals J_load plus m times (L over 2 pi) squared for a screw of lead L. Total kinetic energy E equals half J_total omega squared with omega angular speed. Larger inertia means harder accelerate and more violent stop. In servo selection reflect load inertia to motor shaft and keep ratio to rotor under 10.

2. Numbers and practice

Ignoring friction start time t equals J_total times delta omega divided by T_acc where delta omega is angular speed change in rad/s and T_acc available acceleration torque equals starting torque minus load torque. Example J_total 0.05 kg m2 accelerate 0 to 100 rad/s with T_acc 5 N m gives t 0.05 times 100 over 5 equals 1 s. With friction or varying load use integral or piecewise and leave 20 percent margin.

3. Pitfalls and fixes

Pit one: omitting screw or belt own inertia makes J_total small and start time short in reality late. Pit two: using rated torque as acceleration torque forgetting load takes part so acceleration is slower. Pit three: large inertia frequent start stop overheats the motor. Rule: compute total inertia including screw belt reflected to motor shaft by dividing by ratio squared; use acceleration not rated torque; check heat for frequent starts; add reducer if ratio over 10.

4. Inertia and start time example table

ParameterFormulaExampleNote
Reflected JJ + m(L/2pi)2screw reflectinclude own
Angularomega=2pi n/60100 rad/sn rpm
Start timet=J dW/T_acc0.05x100/5=1suse accel T
Flywheel effectGD2=4gJFrom manualsLegacy data
RatioJ_load/J_m<=10else reducer

5. Notes

Compute total inertia including screw belt reflected to motor shaft by ratio squared then start time t equals J times delta omega over T_acc using acceleration not rated torque; check heat for frequent starts and add reducer if ratio over 10.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Mechanical inertia see GB/T 5226.1 and motor see IEC 60034-1. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Omitting screw belt own inertia makes start time short in reality late
② Using rated torque as acceleration torque forgets load share slower
③ Large inertia frequent start overheats motor

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.