How fast a motor turns must be measured well or control is wrong. Photo electric Hall and tacho generator are the three common field methods with different accuracy cost and noise immunity. This page explains each and where to use it.
Photo electric method fits a code disk on the shaft and a photo sensor reads light dark pulses counting or frequency measuring speed. Advantage: high resolution with 1000 line encoder times four giving 4000 pulses per turn and good accuracy the servo first choice. Drawback: oil on the disk smears counts and the disk can break; alignment matters and at high speed counting overflow needs division.
Hall method places a Hall element near the permanent magnet rotor of a brushless motor and outputs square wave from field change low cost and oil immune. Tacho generator is a small generator whose output voltage is proportional to speed such as 10V at 1000 rpm giving analog direct read fast response and strong noise immunity common on old inverters; drawback is brush wear and poor low speed linearity.
Pit one: photo disk smeared by oil makes counts jump. Pit two: Hall placed near strong magnetic field miscounts. Pit three: tacho brush worn voltage drops to zero misread as stop. Rule: high accuracy servo uses photo electric and keep oil off; low cost brushless uses Hall; inverter analog feedback uses tacho; all need shielded wire and single end ground.
| Method | Principle | Accuracy | Use |
|---|---|---|---|
| Photo | disk pulse count | high 4000 p/r | servo |
| Hall | field square | medium | brushless |
| Tacho | voltage prop speed | medium analog | inverter |
| Gear-tooth pickup | Tooth counting | Medium | Low-speed shafts |
| Care | no oil no mag | ground | low speed poor |
High accuracy servo uses photo electric encoder and keep oil off; low cost brushless uses Hall; inverter analog feedback uses tacho generator. Shield the signal wires and ground at one end; watch disk oil Hall magnetic and tacho brush.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Speed measurement see IEC 60034-2 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.