The centrifugal switch is the automatic door of a capacitor-start motor, opening the start winding at speed. This page explains its action, the common stuck or welded faults, and how to tell it has failed.
Mounted on the shaft, the switch is closed at rest and low speed so the start capacitor and winding are in circuit for high start torque; at 75 to 80 percent speed centrifugal force flips the weights or springs and opens the contacts, dropping the start circuit. Without it the start winding would burn from continuous current.
Failures: contacts welded shut keep the start winding energised, overheating it and bulging the capacitor, with a hot hum; contacts that will not close from oxidation or a stuck spring give no start torque so the motor only hums; a jammed or displaced weight changes the trip speed, causing weak start or burnout; burnt contacts raise resistance and weaken starting. These dominate single-phase no-start calls.
Test de-energised: the start branch should be closed at rest through the switch and open after the rotor is spun. If open at rest the switch or winding is bad; if still closed after spin the switch is welded. Clean oxidised contacts, reset the spring or replace the assembly, then jog to confirm the start winding drops out at speed.
| Fault | Symptom | Measured | Action |
|---|---|---|---|
| Welded closed | Start winding always live | Still closed after start | Replace switch |
| Never closes | No start | Open when stopped | Clean contacts |
| Stuck | Erratic action | Rattling noise | Re-align |
| Burnt contacts | Weak start | High resistance | Dress contacts |
| Shifted | Opens too early | No power | Re-position |
The centrifugal switch opens the start branch at 75%~80% of speed and is the life-saving part of a capacitor-start motor. Welded closed keeps the start winding energised until it burns; never closing means no starting torque at all. Test with power off: the start branch should conduct when stopped and open when spun. Clean the contacts or replace the switch assembly.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Single-phase motors: GB/T 12350; low-voltage apparatus: GB/T 14048 / IEC 60947. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.