Centrifugal switch in single-phase motors: role and faults

The centrifugal switch is the automatic door of a capacitor-start motor, opening the start winding at speed. This page explains its action, the common stuck or welded faults, and how to tell it has failed.

1. How it works

Mounted on the shaft, the switch is closed at rest and low speed so the start capacitor and winding are in circuit for high start torque; at 75 to 80 percent speed centrifugal force flips the weights or springs and opens the contacts, dropping the start circuit. Without it the start winding would burn from continuous current.

2. Numbers and practice

Failures: contacts welded shut keep the start winding energised, overheating it and bulging the capacitor, with a hot hum; contacts that will not close from oxidation or a stuck spring give no start torque so the motor only hums; a jammed or displaced weight changes the trip speed, causing weak start or burnout; burnt contacts raise resistance and weaken starting. These dominate single-phase no-start calls.

3. Pitfalls and fixes

Test de-energised: the start branch should be closed at rest through the switch and open after the rotor is spun. If open at rest the switch or winding is bad; if still closed after spin the switch is welded. Clean oxidised contacts, reset the spring or replace the assembly, then jog to confirm the start winding drops out at speed.

4. Centrifugal switch faults in single-phase motors

FaultSymptomMeasuredAction
Welded closedStart winding always liveStill closed after startReplace switch
Never closesNo startOpen when stoppedClean contacts
StuckErratic actionRattling noiseRe-align
Burnt contactsWeak startHigh resistanceDress contacts
ShiftedOpens too earlyNo powerRe-position

5. Notes

The centrifugal switch opens the start branch at 75%~80% of speed and is the life-saving part of a capacitor-start motor. Welded closed keeps the start winding energised until it burns; never closing means no starting torque at all. Test with power off: the start branch should conduct when stopped and open when spun. Clean the contacts or replace the switch assembly.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Single-phase motors: GB/T 12350; low-voltage apparatus: GB/T 14048 / IEC 60947. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Ignoring a welded switch lets the start winding stay live until the winding burns
② Condemning the winding when only oxidised switch contacts are at fault wastes a good motor
③ Reassembling without a jog test leaves the hidden fault in place to burn again

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.