Three layers: continuity/resistance, inter-winding and core insulation, indirect signs of turn shorts.
Resistance within ±10% of records is healthy; infinity is a broken coil; insulation must be megohms (use a megger, not a DMM).
Turn shorts show as inflated no-load current and local hot spots - confirm with a dedicated surge tester.
| Step | Measure | Pass | Abnormal |
|---|---|---|---|
| 1 | Continuity | Beep / normal R | Open coil |
| 2 | Resistance vs record | ±10% | Turn shorts |
| 3 | Winding-to-winding | Megohms | Damp/aged |
| 4 | To core | Megohms | Breakdown |
| 5 | No-load current | ≤ record | Turn shorts |
| 6 | Heat & noise | Even | Hot spots |
Apply the points above to Testing inductors and transformer windings with a multimeter; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB 1094, GB/T 6451, GB/T 19212 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.