Measuring inductance: LCR meter and bridge basics

Four settings: test frequency, level, equivalent circuit (Ls/Lp), and open/short calibration.

1. How it works

Judge by L plus D/Q: low L with high D hints turn shorts; ferrite parts read differently per frequency.

2. Practice and pitfalls

DC bias matters for SMPS inductors - unbiased readings overstate L; use biased LCR or current-probe tests.

3. Method table

MethodForKeysLimit
LCR meterGeneralf/level/modeNo DC bias
DMM L modeRoughOrder of magnitudeLow accuracy
Volt-amp methodFieldU=2πfLINeeds source
Short-circuit testLeakageShort secondaryPower source
Biased LCRSMPS partsReal conditionCost
Probe & scopeDynamicAt full loadBest reality

4. Notes

Apply the points above to Measuring inductance; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 12115, IEC 61010, IEC 62024-2 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Comparing data across test frequencies
② Wrong series/parallel mode
③ Trusting unbiased readings

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.