To stop a motor fast, plugging and dynamic braking are two old methods, one reverses phase, one dissipates. This page covers fit and risks.
Plugging swaps two supply phases so the field reverses and a counter torque decelerates the rotor sharply, but supply must be cut exactly at zero speed or the motor restarts backward. It is fast (under 2 s) yet draws 5~7× rated current with heavy grid and mechanical shock, so it suits small/medium squirrel-cage motors with infrequent braking like machine spindles and winches, always with a zero-speed switch.
Dynamic braking disconnects AC and feeds DC to the stator, creating a stationary field that damps rotor motion, turning kinetic energy to heat in the rotor. It is smooth, with no reverse risk and no grid shock, but slower and needs a DC source at 0.5~1× rated current. It fits smooth stops where reversal is forbidden, such as elevators and precision tables.
Rule: want fast stop and tolerate shock, use plugging with zero-speed cut; want smooth no-reverse stop, use dynamic. Never plug a high-speed high-inertia load continuously (5~7× current burns windings), and do not rely on dynamic for a giant inertia that must stop in seconds because torque fades at low speed. Do not hand-plug a VFD-driven motor; use decel or brake unit.
| Item | Plugging | Dynamic braking |
|---|---|---|
| Stop speed | Fast <2 s | Slower smooth |
| Current | 5~7× rated | 0.5~1× rated |
| Reverse risk | Yes, cut at zero | None |
| Grid shock | High | None |
| Equipment | Spindles winches | Elevators precision |
Fast tolerant stop uses plugging with zero-speed cut; smooth no-reverse uses dynamic. No plugging on high-inertia continuous; no dynamic for second-stop giant inertia. Never hand-plug a VFD motor.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Braking per GB/T 21207; machines per IEC 60034-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.