A small sine looks clean until you raise the amplitude and the top flattens into a triangle, that is slew rate limiting. This page derives the rate formula, the full-power bandwidth and why SR and GBW are different animals.
Slew rate is the maximum rate of change of the output, in volts per microsecond, set by the charging current of the internal compensation capacitor. An LM358 manages about 0.5V/µs, TL072 about 13, high-speed parts hundreds. When the input demands more, the output cannot follow: sine tops flatten into triangles and square edges become ramps. Slew limiting is a large-signal effect, small signals obey GBW, large ones obey SR, per GB/T 4728.
Full-power bandwidth follows from the worst-case rate of a sine, 2πf times the peak, so the stage is clean only if SR exceeds that, and the full-power bandwidth equals SR over 2π times U_p. For LM358 at 0.5V/µs with 10V peak-to-peak output, a peak of 5V gives about 16kHz before clipping; at 1V peak-to-peak the same part manages about 80kHz. Always run the number at the largest output amplitude, not the small one.
Diagnose on a scope: a sine turned triangle means slew limiting, and shrinking the amplitude restoring the sine confirms large-signal trouble rather than bandwidth. Traps: an LM358 in an audio front end pushing large highs sounds gritty; square-wave circuits check GBW but not SR and the slow edges delay the next stage; paralleling op amps does not double SR. Leave a 3-times margin on SR and pick parts with tens of V/µs for switching and fast signal work instead of audio generalists.
| Part | SR (V/µs) | FP bandwidth at 10Vpp |
|---|---|---|
| LM358 | 0.5 | about 16kHz |
| TL072 | 13 | about 410kHz |
| TLE2072 | 35 | about 1.1MHz |
| OPA627 | 55 | about 1.7MHz |
| RC4558 | 1.7 | about 54kHz |
| Design margin | 3 times | at maximum amplitude |
Slew-rate budgeting fits audio front ends, square generators, pulse amplifiers and video drivers. Compute the needed SR from maximum amplitude and highest frequency with a 3-times margin; when tops flatten, reduce amplitude first to diagnose before swapping parts, sometimes the signal is simply too big.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Op amp large-signal behaviour per GB/T 4728; safety IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.