MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Reactive power compensation: capacitors vs inductors
HomeModels
Table of contents

On this page

Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

Reactive power compensation: capacitors vs inductors

Inductive loads eat reactive power; capacitors supply it locally, QC=P(tanφ1−tanφ2).

1. How it works

Switching: contactors (slow, inrush), thyristor TSC (fast), SVG (continuous). Inductors appear as shunt reactors and detuning filters.

2. Practice and pitfalls

Size for light load too - fixed caps overcompensate at night and raise voltage.

3. Compensation options

MethodResponseCostNotes
Contactor switchingSecondsLowInrush
TSCMillisecondsMediumNo inrush
SVGContinuousHighPhase-balanced
Fixed caps—LowestStable base load
Tuned branches—MediumCompensation+filtering
Shunt reactors—MediumAbsorb capacitive VArs

4. Notes

Apply the points above to Reactive power compensation; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 15576, GB 50227, GB/T 14549, GB/T 12325 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Fixed sizing by full load
② Untuned caps in harmonic environments
③ Missing discharge circuits

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL