Motor load characteristic and drive system stability

Different loads behave very differently with speed and the motor drive system may oscillate or stop depending on the match. This page classifies load types and the stability condition.

1. How it works

Load torque versus speed is the load characteristic. Three common types: constant torque load TL independent of n such as conveyor and crane; constant power load TL inversely proportional to n such as machine tool spindle; square law load TL proportional to n squared such as fan and pump; plus gravity load whose direction is fixed regardless of rotation such as hoist.

2. Practice and pitfalls

Stability condition: at the operating point the slope of the motor torque speed curve dT/dn must be less than the slope of the load characteristic dTL/dn. If the motor slope is steeper the operating point is unstable and the system oscillates or stalls. Pit: using constant torque start method on a fan wastes current unnecessarily; pit: a hoist gravity load descending regenerates and must have a brake resistor or it overvolts the drive.

3. Load type and stability table

Load typeTL vs nTypicalMotor
Constant Tunchangedconveyor cranehard
Constant PTL 1/nspindlewide
SquareTL n2fan pumpsoft start
Gravityfixed dirhoistbrake resist
StabledT/dn < dTL/dnconditionmust hold
Pitfan const Twaste currentwrong start

4. Notes

Loads split into constant torque unchanged constant power TL inversely with n square TL with n squared and gravity fixed direction; stability requires motor curve slope dT/dn below load slope dTL/dn. Fan on constant torque start wastes current; hoist descent needs brake resistor.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machine and drive see IEC 60034-1 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Fan using constant torque start wastes current unnecessarily
② Hoist gravity load descending without brake resistor overvolts drive
③ Ignoring stability slope makes system oscillate or stall