Servo sizing has an old rule that load inertia should not exceed ten times motor inertia but many do not know why or how to calculate it. This page explains rotational inertia and how to match it during selection.
Rotational inertia J measured in kg m2 quantifies how hard it is to accelerate or decelerate a body around an axis. The larger J the harder to speed up or stop. Load inertia must be reflected to the motor shaft by dividing through the square of the reduction ratio so a reducer cuts reflected inertia sharply.
The rule of thumb is safe when inertia ratio is ten or below: the servo is easy to stabilise rigidity can be raised and positioning is fast. Between ten and thirty it still works but needs lower rigidity and a notch filter. Above thirty it becomes hard to tune and prone to oscillation. Steps: estimate load inertia then set reduction ratio then compute reflected inertia then choose a motor with ratio under ten and check torque and speed.
| Scenario | Load inertia | Reduction | Reflected ratio |
|---|---|---|---|
| Direct screw | 0.005 | 1 | 5x |
| 1:5 reducer | 0.02 | 5 | under 1x |
| Belt long | 0.05 | 1 | 50x bad |
| With gear | 0.05 | 10 | 0.5x ok |
| Rule | Jref/Jm | under 10 | else add gear |
| Check | torque speed | both | final verify |
Compute load inertia first then back solve motor rotor inertia; when ratio exceeds ten add a reducer rather than a bigger motor because the reducer divides inertia by the square of the ratio. Keep the load coupling inertia included in the estimate.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servo and mechanical matching see IEC 61800-3 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.