Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

Servo drive alarm code common meaning quick reference

When a servo drive alarms it flashes a code and even old hands must check the table. This page lists the most common over current over voltage overload encoder and following error alarms and what to check first.

1. How it works

Servo alarms fall into three families. Power family: over voltage such as bus voltage above 400V and under voltage from phase loss or weak supply. Motor family: over current short circuit to ground or burnt winding. Signal family: encoder fault battery low or wrong wiring.

2. Practice and pitfalls

Common codes: over current OC check U V W for short to ground and motor burn; over voltage OV check brake resistor and supply; encoder alarm check CN2 shield and battery; following error check load jam and gain. Before reset always find the root cause because repeated reset burns hardware. On site rule: see whether it alarms at power on or during run then see what accompanies it such as noise or heat then check in order.

3. Servo alarm code quick table

Alarm typePossible codePossible causeCheck first
Over currentOCU V W short groundinsulation megger
Over voltageOVno brake resistorresistor supply
EncoderAL encCN2 batteryshield battery
Over loadOLjam heavyload free spin
Follow errAL FEgain jamtune load
Under voltUVphase losssupply
Resetroot causerepeated resetburns IGBT

4. Notes

Classify the alarm first: power family checks supply wiring motor family checks resistance and insulation signal family checks wire and battery. Always find root cause before reset because repeated reset burns hardware. Verify with megger and scope.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Drive fault and electrical safety see GB/T 5226.1 and equipment protection see IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Resetting without root cause turns a transient fault into permanent IGBT burn
② Power on over current yet forcing power risks confirmed short
③ Encoder wire parallel to high current wire misread as hardware

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL