The voltmeter forms a divider with the source impedance: reading = true × Rm/(Rm+Rs).
Analog 20kΩ/V meters break megohm circuits; 10MΩ DMMs still load 10MΩ sources - use FET-input or electrometer meters.
Current jacks add series impedance too; sensing voltage across a known resistor is safer in high-Z loops.
| Meter | Zin (V mode) | Good for | Limit |
|---|---|---|---|
| Analog 20kΩ/V | 200kΩ @10V | Power circuits | Massive loading |
| Standard DMM | 10MΩ | General service | Megohm sources |
| FET-input DMM | 10GΩ class | Precision electronics | Cost, protection |
| Bench 6.5-digit | 10GΩ class | Metrology | Complexity |
| Scope 1× probe | 1MΩ | Dynamic signals | Capacitive loading |
| Scope 10× probe | 10MΩ | General | Half-attenuated? -1/10 |
Apply the points above to Meter input impedance and weak; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 13978, GB/T 15289 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.