Meter input impedance and weak-signal measurement

The voltmeter forms a divider with the source impedance: reading = true × Rm/(Rm+Rs).

1. How it works

Analog 20kΩ/V meters break megohm circuits; 10MΩ DMMs still load 10MΩ sources - use FET-input or electrometer meters.

2. Practice and pitfalls

Current jacks add series impedance too; sensing voltage across a known resistor is safer in high-Z loops.

3. Meter impedance quick table

MeterZin (V mode)Good forLimit
Analog 20kΩ/V200kΩ @10VPower circuitsMassive loading
Standard DMM10MΩGeneral serviceMegohm sources
FET-input DMM10GΩ classPrecision electronicsCost, protection
Bench 6.5-digit10GΩ classMetrologyComplexity
Scope 1× probe1MΩDynamic signalsCapacitive loading
Scope 10× probe10MΩGeneralHalf-attenuated? -1/10

4. Notes

Apply the points above to Meter input impedance and weak; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 13978, GB/T 15289 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Probing high-Z nodes with a standard DMM
② Using 1× scope probes on high-Z circuits
③ Blaming the circuit before ruling out loading

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.