MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Panasonic servo motor selection software and parameter config
HomeModels
Table of contents

On this page

Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

Panasonic servo motor selection software and parameter config

Panasonic servo has high share in OEM equipment and the official selection software saves much calculation. This page explains how to use the selector and the basic parameter path with field pitfalls.

1. How it works

Panasonic official selection software such as MINAS Selection lets you fill mechanical type load inertia accel time speed and duty then outputs a model with inertia ratio and peak torque check. Use it to avoid manual mistakes and read the green ok red over flags.

2. Practice and pitfalls

MINAS A6 parameters are set by PANATERM software or panel. Control mode Pr0.01 (0 position 1 speed 2 torque). Electronic gear uses Pr0.08 etc. Pit one: filling inertia in wrong unit kg m2 versus kg cm2 gives ten thousand times error. Pit two: A6 electronic gear default unit differs from old so copying old values gives wrong pulse equivalent. Always recheck after import.

3. Panasonic servo selection config table

StageTool or paramActionPoint
SelectMINAS softwarefill dutyinertia peak
Control modePr0.010/1/2match process
GearPr0.08calcpulse per mm
TunePANATERMautostable
Pit unitkg m2not cm2ten thousand x
Pit geardefault unitrecheckwrong equiv

4. Notes

Use the official selector to fill duty and read inertia ratio and peak torque check green ok red over; set mode gear and IO with PANATERM and recheck gear unit because A6 default differs from old models. Verify direction after download.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servo selection and safety see GB/T 5226.1 and interface see IEC 61800-3. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Selector inertia unit wrong kg cm2 as kg m2 ten thousand times off
② A6 electronic gear default unit copied from old gives wrong equivalent
③ DI source sink mismatch with PLC prevents enable

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL