Reset circuits: RC sizing and power-up timing

Reset must hold until the clock and supply are stable; the RC charges to release it after tRST.

1. How it works

Sizing: τ from tRST with 2× margin, C=0.1~1μF, R=10k~100k, plus a discharge diode.

2. Practice and pitfalls

Slow rails break the implicit assumption - supervisor chips with BOR are the robust default.

3. Reset options

SchemeReliabilityCostUse
RC+diodeModerateLowestSimple boards
Supervisor ICHighLow-mediumDefault choice
WDT+supervisorHighestMediumIndustrial
Multi-rail supervisorHighMediumComplex rails
Internal POR onlyVariesZeroConsumer
Long reset tracesPoor—Forbidden

4. Notes

Apply the points above to Reset circuits; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 17626 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Designing at the datasheet minimum
② Reset lines bundled with power wires
③ Relying on RC through brownouts

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.