Four specs matter: tolerance, TCR, long-term drift and power coefficient; tolerance alone is the starting point.
Ratio accuracy comes from tracked pairs or thin-film networks - drift cancels between matched elements.
Calibrate once for tolerance, then budget TCR over your temperature span; derate power to 1/4 because self-heating is error.
| Type | Tolerance | TCR | Use |
|---|---|---|---|
| Thick film | ±1% | ±100ppm/℃ | General |
| Thin film | ±0.1% | ±25ppm/℃ | Sensing |
| Precision film | ±0.05% | ±10ppm/℃ | Instrumentation |
| Metal foil | ±0.005% | ±2ppm/℃ | Reference |
| Manganin shunt | ±0.1% | <20ppm/℃ | High current |
| Matched network | Ratio 0.05% | Tracking ±5ppm | Divider, bridge |
Apply the points above to Precision 0.1% resistors in sampling circuits; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per IEC 60115, GB/T 5729, GB/T 6379 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.