Interference that moves both inputs together is common mode, the signal you want is their difference, and the CMRR says how well the op amp rejects the former. This page defines both terms and turns the datasheet number into real error.
The differential signal is the voltage difference between the inputs and is what you amplify; the common-mode signal is their average, typically mains hum or ground bounce, and is what you reject. The real output equals the differential gain times the difference plus the common-mode gain times the average. Differential gain is huge, around 100 thousand, and common-mode gain should vanish, definitions per GB/T 4728.
CMRR is the ratio of differential to common-mode gain, quoted in dB: ordinary parts manage 70 to 90dB, precision parts 100 to 120dB. Translated to error, 80dB means a factor of ten thousand, so 1V of common mode becomes 0.1mV of equivalent differential input, or 10mV at the output of a gain-of-100 stage. But CMRR degrades with frequency, from 100dB at DC to maybe 60dB at 10kHz, so check the curve for high-frequency common-mode work. Resistor mismatch in subtractors and asymmetric wiring drag CMRR down another 20 to 40dB.
Improve it with 0.1 percent or network resistors in the subtractor, twisted shielded pairs with symmetric impedances, and an instrumentation amplifier, the three-op-amp structure that keeps 100dB without depending on external matching, when common mode is large. Traps: trusting the DC figure at high frequency, exceeding the input common-mode range which saturates the part, and assuming grounding fixes common mode when a ground loop converts it to differential. Diagnose with two probes on the two inputs and subtract.
| Item | Typical | Note |
|---|---|---|
| Ordinary op amp CMRR | 70 to 90dB | 1V CM gives 0.1mV error |
| Precision CMRR | 100 to 120dB | bridges and thermocouples |
| CMRR vs frequency | minus 30dB at 10kHz | read the curve |
| Resistor mismatch | minus 20 to 40dB | use 0.1 percent parts |
| Twisted shielded pair | preserves CMRR | symmetric impedances |
| Instrumentation amp | 100dB or more | no external matching |
CMRR matters for bridges, long lines and motor current sensing where common mode is large. Estimate the common-mode amplitude and frequency, read the CMRR curve at that frequency, keep resistor precision high, and attenuate or isolate first when common mode exceeds the input range.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Op amp parameter definitions per GB/T 4728; safety IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.