Open a three phase induction motor and you find a stator, a rotor, laminated cores, bearings, end bells and a fan. This page walks the parts line by line so a repairer knows which block to keep and which to swap.
The stator is the stationary field generator: a frame of cast iron or aluminium, a core of 0.35 to 0.5 mm silicon steel laminations to cut eddy loss, and three phase windings laid in slots and connected star or delta. The winding insulation class, say F at 155 C, sets the temperature ceiling, and the most common failure is slot insulation breakdown causing turn to turn short.
The rotor is the driven member: a laminated core with a squirrel cage of aluminium or copper bars shorted by end rings, plus a shaft of tempered 45 steel. The air gap to the stator is only 0.2 to 1.5 mm, so uneven gap invites unbalanced magnetic pull and vibration. End bells carry the bearings and seal the machine; deep groove ball bearings of the 6200 or 6300 series run on grease filled to one third or half the cavity, since over greasing heats them. The external fan and cowl remove heat, and the terminal box holds the U V W links and the ground, whose tightness and phase order matter on reassembly.
| Part | Material or spec | Main function |
|---|---|---|
| frame | cast iron or aluminium | support, cooling, protection |
| stator core | 0.35 to 0.5 mm laminations | conduct flux, hold windings |
| stator winding | copper, F or H class | make rotating field |
| rotor cage | aluminium or copper bars | induce current, make torque |
| shaft | tempered 45 steel | transmit mechanical power |
| bearing | 6200 or 6300 series | support rotor, low friction |
| fan and cowl | plastic or steel | forced air cooling |
Structure is the repair map. The winding insulation and the air gap are the two lifelines: protect slot insulation and keep the gap even during assembly. Grease the bearing to one third or half, check the IM mounting code and pole count before a swap so direction and interface match.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Safety of small rotating machines per GB/T 14711; terminal marking per GB/T 1971. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.