One MOS cannot carry the current, so you parallel several to expand, but one blows at power-on because sharing was poor. This page covers how to share current and how to fit each gate resistor.
Why parallel parts skew: same-type MOS have spread V_th and Rds(on). The lower V_th, lower Rds(on) part takes more current and runs hotter; Rds(on) rises with temperature, which in theory self-balances, but uneven cooling makes the hot one higher resistance and starves, leaving a local hot spot. Current splits 30/70 or one device overloads, per GB/T 4728.
Design for sharing. Give each MOS its own gate resistor, never one shared R_g, so switching is synchronous and cross-coupling ring is reduced. Keep source traces short and symmetric so each V_GS matches. Select parts binned to close V_th and Rds(on). Cool each part equally to avoid one hot one cold. Derating total current to N times rating times 0.7.
Traps: one shared gate resistor makes switches unsynchronised and rings to failure; unequal source trace length lets the near part win current; no derating forces N times current and discrete spread overloads one. Check with an IR camera, the case temperature difference should be under 10C; scope each gate for identical waveform.
| Point | Method | Result |
|---|---|---|
| Gate R | each own | shared rings |
| Source | sym short | no hog |
| V_th bin | match parts | less skew |
| Cooling | each own | no hot spot |
| Derating | x 0.7 | no overload |
| Temp | delta under 10C | sharing ok |
Paralleling fits high-current supplies, motor drives and inverters. Use independent R_g per part, symmetric layout, binned same-batch parts, uniform cooling and derating. Do not share the gate resistor nor skip cooling.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Power MOS parallel per GB/T 4728; safety IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.