The 7805 three terminal regulator typical circuit

The 7805 is the most common three terminal regulator, taking 7 to 35 V in and holding 5 V out with just two caps. This page covers the typical hookup, cooling and the often missed decoupling traps.

1. How it works

Pin 1 is input, 2 ground, 3 output. A 0.33 microfarad electrolytic at the input to ground filters low frequency and a 0.1 microfarad ceramic at the output filters high frequency, the datasheet minimum. Input must exceed output by at least 2 V dropout, so above 7 V input to hold 5 V; too low and output sags. Rated current is about 1 A and needs cooling.

2. Practice and pitfalls

Dropout loss is (Uin minus 5) times I, so 12 V in at 1 A wastes 7 W and demands a heatsink, junction by thermal resistance. Do not push input high needlessly; 9 to 12 V from rectified mains is ideal. Below 2 V dropout it leaves regulation with big ripple, so many who feed only 6 V cannot hold 5 V.

3. 7805 key points

ItemRequireValue
Vinabove 7 V9 to 12 V best
Dropoutabove 2 Velse sags
In cap0.33 uF plusLF filter
Out cap0.1 uF cerHF filter
Currentto 1 AL05 only 100mA
Coolsinkthermal R

4. Notes

Typical 7805 is a cap at input and output, dropout 2 V or more, current to 1 A with a sink. Keep the 0.1 microfarad ceramic right at the pin to stop oscillation, do not feed only 6 V, and never use 78L05 for 1 A.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Three terminal use per GB/T 5226.1; device data to IEC 60747 and GB/T 12350. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Output cap not at the pin lets HF oscillation and spikes; put 0.1 uF ceramic close.
② Feeding only 6 V cannot hold 5 V; dropout is insufficient and output sags.
③ Using 78L05 rated 100 mA for 1 A trips thermal shutdown; use 7805 with sink.

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.