Mapping imported motor nameplate to Chinese standards

Imported plates read 460 V, 60 Hz and HP; replacing by domestic rules fails. This page maps and converts imported plates to GB/IEC.

1. How it works

North-American motors are often 460 V 60 Hz versus GB 380 V 50 Hz. Connecting 460 V to 380 V/50 Hz raises flux (lower frequency) yet lowers torque (lower voltage), so the motor is weak and hot. Fix: set the VFD to 460 V 60 Hz or use a transformer, or pick a dual-voltage motor. 415 V (UK) or 400 V (IEC) near 380 V can be used directly. Trap: plugging a 460 V motor into 380 V starves torque and over-currents.

2. Numbers and practice

Imported plates use English: HP (×0.746=kW), RPM, FLA (full-load amps = In), SF (service factor, >1 means short overload), INS CLASS, ENCL, PF, EFF. Map HP×0.746; 20 HP≈14.9 kW. FLA is In. SF>1 allows brief overload. NEMA and IEC designs differ in start curve for the same HP.

3. Pitfalls and fixes

Replacement: convert imported specs to GB then choose domestic, watching poles (60 Hz 4-pole ns=1800 vs 50 Hz 1500, speed differs, check equipment match). VFD entry: record FLA, voltage, frequency as on the plate, not domestic rules. Traps: taking HP as kW undersizes by 25%; a 60 Hz motor on 50 Hz drops speed 17% and mismatches; convert NEMA enclosure to IP (TEFC≈IP54).

4. Import to GB mapping

ImportMeaningGB
HPHorsepower×0.746 kW
FLAFull-load A=In
460V/60HzNA voltageVFD/transformer
TEFCClosed fan≈IP54
SFService factor>1 overload

5. Notes

Imported 460 V/60 Hz must not connect to 380 V/50 Hz; use VFD or transformer. HP×0.746=kW, FLA=In, TEFC≈IP54. A 60 Hz motor on 50 Hz drops 17% speed and mismatches. Enter VFD from the imported FLA/voltage/frequency, not domestic rules.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Machines per IEC 60034-1; NEMA MG-1 reference. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① 460 V plugged to 380 V starves torque
② Taking HP as kW undersizes by 25%
③ 60 Hz motor on 50 Hz mismatches speed 17%

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.