Parallel-shunt current sampling circuits

Sense resistor in the path: U=I×Rs; parallel resistors share power and extend range.

1. How it works

Three constraints: enough signal (50~100mV full scale), acceptable I²R power, low TCR (manganin).

2. Practice and pitfalls

Kelvin (4-wire) connections are mandatory; build the error budget from self-heating, TCR and ADC reference - not resistance alone.

3. Sampling options

SchemeR/powerAccuracyUse
Single manganin1mΩ/10W@100A0.5%Bus bars
Two parallel2mΩ each0.5%Power sharing
Four chip 251210mΩ each1%BMS packs
Hall sensorLossless1~2%Isolated
Rogowski coilLossless1%AC high current
CTLossless0.2%Power frequency

4. Notes

Apply the points above to Parallel; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per IEC 61010, GB/T 7676, GB/T 38661 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Selecting sense resistors by cold accuracy
② Non-Kelvin sense taps
③ Shunts where isolation is required

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.