Too large or too small a capacitor both cause trouble; the value must follow motor power. This page sizes start and run capacitors, picks voltage rating, and debunks the bigger-is-better myth.
A start capacitor is roughly 200 to 400 microfarads per kilowatt at 220 V, so 0.75 kW takes about 200 uF and 1.5 kW about 400 uF. Too small means weak start; too large means start current surges and the centrifugal switch may fail to open, burning the start winding. It is short-time rated, use 450 V AC film type. A run capacitor is far more precise, about 20 to 50 uF per kilowatt; 0.75 kW uses 20 to 25 uF. Wrong value unbalances current and heats the motor.
Always use self-healing metallised polypropylene rated 450 V AC or above for continuous run duty, never an electrolytic or DC capacitor which bursts on AC. Replace within plus or minus 10 percent of the original; bigger is not better. After fitting, measure winding currents for balance and check temperature rise before returning the motor to service. A start capacitor left connected continuously will bulge within hours.
| Power | Start capacitor | Run capacitor | Voltage rating |
|---|---|---|---|
| 0.37 kW | 100 uF | 10 uF | 450 V |
| 0.75 kW | 200 uF | 20 uF | 450 V |
| 1.1 kW | 300 uF | 30 uF | 450 V |
| 1.5 kW | 400 uF | 40 uF | 450 V |
| 2.2 kW | 500 uF | 50 uF | 450 V |
Rough rules: start capacitor 200~400 uF per kW, run capacitor 20~50 uF per kW, always 450 V AC self-healing film type. Replace with the original value within plus or minus 10%; bigger is not better. Never substitute electrolytic or DC capacitors, and never leave a start capacitor permanently connected, or it will bulge within hours.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Motor capacitors: GB/T 3667 / IEC 60252; single-phase motors: GB/T 12350. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.