Connection method and voltage correspondence on the plate

The plate says Δ/Y 380/660 V; wrong connection means weak or burnt. This page explains star-delta mapping and how to wire dual-voltage motors.

1. How it works

The three windings have six ends. Delta applies line voltage per phase; star applies line/√3. So for one motor, star allows √3 (1.732) times the delta voltage. Plate Δ/Y 380/660 V means: 380 V uses delta, 660 V uses star, same power. Reverse it: 380 V on star gives only 220 V per phase, flux and torque collapse; 660 V on delta over-voltages and burns insulation.

2. Numbers and practice

Dual-voltage motors (220/380 or 380/660) have six terminals; low voltage uses delta (windings in parallel for low V high I), high voltage uses star (series for high V low I). Follow the terminal diagram: U1U2/V1V2/W1W2 linked as delta or brought out as star centre. Traps: wiring delta on a 660 V supply over-voltages; star on 380 V gives no torque and overheats; mislabeling terminals reverses phase and rotation.

3. Pitfalls and fixes

First read supply: most plants are 380 V three-phase, so dual-voltage motor goes delta. If supply is 660 V (mines, some EU) use star. Single-voltage motors have one connection, do not alter. Star-delta starting motors must be delta-rated with six terminals. Rule: voltage must match connection, delta for low, star for high; wrong is weak or burnt. Verify terminals with a meter, not memory.

4. Connection vs voltage

PlateConnectionVoltage
Δ/Y 380/660Delta at 380Star at 660
Δ/Y 220/380Delta at 220Star at 380
Single ΔDelta onlyRated
Y onlyStar onlyRated
WrongWeak or burnVerify

5. Notes

Dual-voltage motors use delta at low voltage and star at high, same power. 380 V supply uses delta, 660 V uses star. Reverse gives weak run or over-voltage burn. Follow the terminal diagram and verify with a meter.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Machines per IEC 60034-1; connection per GB/T 755. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Delta on 660 V over-voltages and burns insulation
② Star on 380 V gives no torque and overheats
③ Mislabeled terminals reverse phase and rotation

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.