Fast switching makes electromagnetic interference that travels down the lines and radiates into space; ignore it and you upset other gear and yourself. This page covers the sources and input output filtering.
The switch turning fast makes dv/dt and di/dt spikes that couple through transformer parasitic capacitance to the secondary as common mode, and conduct down the input and output leads as differential mode. Diode reverse recovery also spikes. This noise spans tens of kHz to tens of MHz, conducted and radiated, dirtying the mains, tripping nearby sensitive gear and raising your own ADC floor.
At the input add a common mode choke with X and Y capacitors; the choke strangles common mode on both lines, X caps shunt differential across the line and Y caps shunt common mode to ground. At the output add beads and a pi filter. Shield the transformer, cut leakage and add an RCD clamp for spikes. Short the HF loop, single point ground and pour ground to shrink loop area.
| Measure | Action | Note |
|---|---|---|
| CM choke | strangle CM | dont reverse |
| X cap | diff mode | across line |
| Y cap | common mode | true ground |
| Bead | clean out | pick freq |
| Shield | less radiate | bond case |
| RCD clamp | soak spike | power loss |
EMI relies on input common mode choke with X and Y caps, output bead pi filter, transformer shield and RCD clamp. Ground the Y cap truly, do not reverse the choke, mount the filter at the inlet, and remember output filtering too plus the Y cap safety limit.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: EMC and filtering per GB/T 5226.1; EMI limits to GB/T 17626 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.