MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Range-switching networks inside a multimeter
HomeModels
Table of contents

On this page

Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

Range-switching networks inside a multimeter

Voltage ranges add series multipliers (the Ω/V figure); current ranges add parallel shunts (0.1Ω at 1A).

1. How it works

Ohms ranges use an internal battery and reversed-scale readout; DMMs use ratiometric measurement.

2. Practice and pitfalls

Knowing the network explains the golden rule: jack and dial must match the quantity before probing.

3. Range network table

RangeResistor roleTypicalKey point
DC voltsSeries multiplier20kΩ/VBigger range, bigger R
AC voltsMultiplier+rectifierDiode drop errorLow-end nonlinearity
DC ampsParallel shunt0.1Ω @1ARing shunt network
OhmsInternal source1.5/9V cellDe-energized only
DMMRatiometric10MΩ inputAuto ranging
HV probeExternal divider100:1Rating & bandwidth

4. Notes

Apply the points above to Range; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 7676, GB/T 13978 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Probing volts from the current jacks
② Judging semiconductors on the Ω range
③ Ignoring Ω/V on high-impedance circuits

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL