Below base speed you control voltage, above base speed you weaken the field: this pyramid is the skeleton of every DC drive. Knowing where the border lies and which loads fit each region ends the selection debate.
Base speed is the rated speed at rated flux. Under it, flux stays rated, the torque ceiling is fixed by commutation and temperature, and power rises linearly with speed: the constant-torque region. Above it, voltage has hit the converter and insulation ceiling, so flux is reduced to climb in speed; the torque ceiling falls inversely with flux while power stays roughly constant: the constant-power region. The nameplate rated point is exactly the border, carrying rated voltage, flux, speed and torque at once.
Match the load: winders and finishing passes of machine spindles are constant-power and live happily in the weakening region; hoists, extruders and conveyors demand full torque at any speed and must stay in the voltage region. Misplacing a constant-torque load into field weakening means the torque ceiling collapses as speed rises and the drive trips on current at every load step. On the floor, remember the ordering rule: to speed up, weaken the field first; to slow down, restore the field before reducing voltage, and never weaken below about 40 to 50 percent of rated excitation.
| Item | Voltage region (below base) | Weakening region (above base) |
|---|---|---|
| control variable | armature voltage U | field flux Φ |
| torque ceiling | constant (commutation and heat limited) | falls inversely with speed |
| power ceiling | rises linearly with speed | roughly constant |
| curve stiffness | unchanged (parallel lines) | softens |
| suited loads | constant torque | constant power |
| main risk | poor cooling at low speed | overspeed and commutation stress |
| protection | overcurrent, undervoltage | field failure, overspeed at 1.1~1.15x |
Rule of thumb: plan the weakening region up to 1.5 times base speed with torque at 65 percent of rated, keep power at rated and add 10 percent margin. Beyond that, change the motor or add gearing instead of pushing the drive.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 3886.1 for DC drive ratings and performance; protection coordination per GB/T 5226.1 (IEC 60204-1). Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.