A household RCD is one component with many wrong choices: wrong rating, wrong sensitivity or neutral wired past it. This page gives the per circuit selection table and the wiring rules that keep nuisance trips away.
End of circuit protection for people uses 30 mA sensitivity. Lighting circuits run a 10 A breaker, general socket circuits 16 A, and air conditioning 20 to 32 A depending on the unit, all with 30 mA RCD function. The main incomer carries a selective 100 to 300 mA time delayed RCD whose job is fire prevention and backup, not personal protection, so a socket fault trips the final circuit instead of the whole house. Electromagnetic RCDs keep working when the neutral is lost and cost more; electronic ones need both lives live and are the common budget choice.
Wiring rules decide whether the device can work at all: both line and neutral of the protected circuit must pass through the RCD, the PE conductor never passes through it, and after the device the neutral must never touch earth or another circuit neutral or the differential current leaks and trips at random. Test the button monthly; if it does not trip, replace the unit. Split loads by circuit rather than relying on one big RCD, because a single 30 mA device over an entire house converts one leaky appliance into a blackout.
| Position | Rated current | Residual current | Purpose |
|---|---|---|---|
| Lighting circuit | 10A | 30mA | Personnel protection |
| Socket circuits | 16A | 30mA | Personnel protection |
| Air conditioning | 20 to 32A | 30mA | Personnel protection |
| Main incomer | 63A | 100 to 300mA | Fire protection, delayed |
| Type choice | None listed | None listed | Electromagnetic more robust |
Protect people with 30 mA at every final circuit and the installation with a delayed 100 to 300 mA device upstream. Route both poles through the RCD, keep PE outside it, and test monthly.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Residual current devices follow GB/T 6829 and GB 13955, with household safety per IEC 61008 and GB 50054. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.