Servo torque speed position control mode difference

A servo drive has three basic modes: torque speed and position. Choose the wrong mode and tension and positioning both go wrong. This page compares the commanded quantity feedback and wiring of the three modes.

1. How it works

In torque mode the controller sends a torque command such as analog plus minus 10V or a bus value and the drive guarantees motor current hence torque. Speed mode takes a speed command and locks rpm. Position mode takes a position command and stops at the target. Each mode closes different loops and exposes different feedback.

2. Practice and pitfalls

Modes switch by a parameter or control word on the same drive and can change online. Wiring differs: torque and speed modes often use analog command plus enable while position mode uses pulse train or bus position command. Choose by process: winding and constant pressure use torque mode with limit; conveyors and spindles use speed mode; CNC feeds and robots use position mode.

3. Servo three mode comparison

ModeCommandFeedbackUse
Torquetorque cmdcurrentwind tension
Speedspeed cmdrpmbelt spindle
Positionposition cmdencoderCNC robot
Switchparam wordonlinesame drive
Limitset ceilingprotecttorque needs cap

4. Notes

Choose mode by process: use torque mode with a limit for constant tension or torque cap use speed mode for stable rpm and position mode for accurate arrival. On bus systems set the mode word correctly and never run position mode without a home reference.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Servo mode and interface see IEC 61800-3 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Torque mode without upper limit overloads and burns motor
② Using speed mode as position drifts and never stops
③ Position mode pushed by external force alarms as fault

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.