Overheating is the clearest warning before a motor burns, but the heat source may be load, supply, bearing or cooling. This page lists common overheat causes with fixes so you can cool the machine down by the table.
Judge heat by temperature rise and surface temperature against insulation class: B 130 C, F 155 C, H 180 C for the winding, with the frame typically 20 to 40 C cooler. On site a spot gun on the frame should alarm above 90 to 100 C for an F class machine. Standards cap rise at 80 K for B and 105 K for F over a 40 C ambient, and above that insulation ages fast, roughly halving life per 10 C. On overheating, stop and map the temperature distribution to locate the source.
Causes split into four: excess load or mechanical drag with current over rated and hot bearing; supply trouble of high or low or unbalanced voltage and single phase; poor cooling from failed fan, blocked duct, hot ambient or weak self cooling at low VFD frequency; and bearing fault from dry grease, tight clearance or debris. They look different: load heats whole machine with high current, poor cooling heats the fan side locally, bad bearing heats the bearing seat with noise. Act by cause: reduce load or fit a bigger motor, fix supply, clear duct and fan or add forced cooling, or stop and regrease or change bearing. Temporarily derate and watch temperature but remove the root, and log every overheat event with temperature, current and cause.
| Cause | Symptom | Fix |
|---|---|---|
| overload or drag | current over rated whole hot | derate or fix mech |
| voltage fault | current swings hot | fix supply contacts |
| poor cooling | fan side local hot | clear fan force cool |
| bearing fault | bearing seat hot noise | regrease change bearing |
| low freq weak cooling | slow whole hot | forced cool derate |
Cap heat by insulation class, alarm at frame over 90 to 100 C and respect the 80 or 105 K rise limit. Treat the four cause families by their look, derate as emergency but kill the root, and keep the duct clear, fan sound, grease fresh and temperature trend logged so overheating never reaches the limit.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rating and temperature rise per GB/T 755 (IEC 60034-1); safety per GB/T 14711. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.