Capacity is estimated from a formula, but a correct choice also needs voltage rating, ESR, ripple current and temperature. This page shows how to derive capacity from load current and the hard criteria to check on the bench.
Working backwards from ripple, C must be at least I times t divided by delta U. At 50 Hz full wave t is 10 ms, so for 2 A and 2 V allowed ripple C is at least 0.01 F or 10000 microfarad. That is the bare minimum; multiply by 1.5 to 2 times margin because electrolytics age and lose capacitance, often dropping to seventy percent of label.
Four hard criteria matter beyond microfarads. Rate voltage at peak times 1.5, so 400 V class after 220 V rectification. Ripple current rating must exceed the actual AC current through the cap or it overheats. Lower ESR means less ripple under load, and a 105 C part lasts about twice as long as 85 C in a hot cabinet.
| Criterion | Rule | Field value |
|---|---|---|
| Capacitance | C at least I t over delta U | times 1.5 to 2 margin |
| Voltage | peak times 1.5 | 400 V after 220 V |
| Ripple current | above actual | derate when hot |
| Temperature | above cabinet | 105 C lasts longer |
| ESR | lower better | key under load |
| Lead pitch | match original | 5/7.5/10 mm |
Derive minimum capacity from load current, then pass the four gates of voltage, ripple current, ESR and temperature. For service, prefer the same high temperature low ESR type, and keep parallel caps identical with correct polarity.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Capacitor selection and life per GB/T 2693; equipment safety design to GB/T 5226.1 and IEC 60384. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.