A servo is not a particular motor construction but a feedback driven system that positions and speeds precisely on command. This page explains how a servo differs from an ordinary motor and how encoder feedback turns an open loop into a closed one.
A servo consists of a motor an encoder or resolver and a drive. The drive receives a position or speed command from the controller and reads the encoder feedback every cycle then subtracts actual from commanded to get an error and drives the motor to cancel that error. An ordinary motor just runs when powered while a servo constantly compares where it is with where it should be achieving positioning within one pulse.
The closed loop runs three nested rings: the position ring outputs a speed command the speed ring outputs a current command and the current ring drives torque directly. Any disturbance such as heavier load or voltage dip is corrected at once. If load suddenly rises and speed drops 50 rpm the speed feedback falls and the speed ring raises current to pull speed back all within milliseconds which an open loop step motor cannot do.
| Item | Servo closed loop | Open loop motor | Difference |
|---|---|---|---|
| Feedback | encoder real time | none | servo knows position |
| Accuracy | within one pulse | step angle accum | servo far better |
| Disturbance | auto correct | no correct | servo holds speed |
| Overload | alarm stop | stall burn | servo safer |
| Holding torque | holds until off | none | servo locks |
| Cost | high | low | choose by need |
Ask first whether you need spin or precise positioned hold. Fans and pumps are fine with inverter async motors while positioning synchronisation and constant tension need a servo. Set the following error limit small during commissioning to protect accuracy and prevent crash.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Electrical safety and drive systems see GB/T 5226.1 and rotating machine general requirements see IEC 60034-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.