Reading the dual-capacitor (CSR) wiring diagram

A CSR motor carries two capacitors and a misread diagram leads to wrong wiring. This page explains how the start capacitor, run capacitor and centrifugal switch connect, what the terminal symbols mean, and how to test.

1. How it works

In capacitor-start-run the auxiliary winding has a run capacitor C_run permanently across it, and a start capacitor C_st in series with the centrifugal switch K parallel to that. At start both capacitors act, giving strong torque; at 75 to 80 percent speed K opens and C_st drops out, leaving C_run for running. It combines the best of start and run types. Terminal boxes label the main winding U1/U2, auxiliary Z1/Z2, and the capacitor terminal C; the start capacitor branch is the one controlled by the switch.

2. Practice and pitfalls

Test de-energised: the main and auxiliary windings each show a steady resistance, and the start branch is closed at standstill through K then opens when spinning. A bulged start capacitor or a run capacitor lost over 20 percent of value makes starting slow or weak. Replace both to original value at 450 V AC. Identify the switch-controlled capacitor on the diagram before touching wires; guessing shorts the capacitor and bursts it.

3. Terminal meanings in a two-value capacitor (CSR) motor

TerminalMeaningConnectionHow to tell
U1/U2Main windingSupplyStable resistance
Z1/Z2Auxiliary windingVia capacitorsOpen circuit path
C terminalCapacitor pointBridgeMeasure capacitance
KCentrifugal switchIn start branchContinuity
EarthFrameGroundInsulation

4. Notes

The heart of a CSR circuit: the run capacitor sits across the auxiliary winding, with the start capacitor and centrifugal switch in series alongside it. Read the diagram to see which capacitor the switch controls. Replace capacitors with the original value at 450 V AC; swap out a bulged start capacitor or a run capacitor that lost over 20% of its value. Winding resistance and switch continuity tests locate most faults.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Single-phase motors: GB/T 12350; capacitors: GB/T 3667 / IEC 60252. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Using the start capacitor as a permanent run capacitor ends in a bulged, dead unit
② Misreading the switch position leaves the start capacitor permanently live and burns the winding
③ Guessing terminals instead of reading the diagram shorts the capacitor, which bursts

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.