MOULDLKnowledge BaseElectrical Knowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Electrical Knowledge Base › Buck converter duty cycle and input output relation
HomeModels
Table of contents

On this page

Electrical & Electronic Basics (600 articles)

Quick Reference

  • PLC & Programming
  • Electrical & Electronic Basics (monthly)(每月更新中)
  • Electrical Control & Drawings (monthly)(每月更新中)
  • Drives & Actuators (monthly)(每月更新中)
  • Sensors & Detection (monthly)(每月更新中)
  • Industrial Communication & Networks (monthly)(每月更新中)
  • HMI & Host Systems (monthly)(每月更新中)
  • Industrial Robots & Motion Control (monthly)(每月更新中)
  • Mechatronic System Integration (monthly)(每月更新中)
  • Fault Diagnosis & Standards (monthly)(每月更新中)

Buck converter duty cycle and input output relation

In a Buck the duty cycle sets the output voltage directly, with D equals Uout over Uin as the core equation. This page covers duty versus voltage, current and inductance and the tuning traps.

1. How it works

Ideally in continuous conduction Uout equals D times Uin, where D is the on time fraction, so D equals Uout over Uin. For 12 V to 5 V D is about 0.42. Average inductor current equals output current and peak ripple is Uout times (1 minus D) times T over L. Bigger D, lower frequency or smaller L all raise ripple current; keep D near 0.3 to 0.6 for the calmest stress.

2. Practice and pitfalls

Output current is the inductor average, so pick saturation current above peak (average plus half ripple) with margin. Higher frequency shrinks the inductor but raises switching loss; too small D unbalances stress, too large D heats the low side switch. When input moves, D auto adjusts to hold output, which is the essence of closed loop regulation.

3. Buck duty and parameters

In outDuty DNote
12 to 5 Vabout 0.42common
24 to 5 Vabout 0.21D small
24 to 12 Vabout 0.50mid
12 to 3.3 Vabout 0.28ripple big
Ripple dIL1/L fL sets
Hi freqsmall Lloss up

4. Notes

Buck output is D times Uin; trim voltage via the feedback divider, never by forcing duty or the loop unlocks. Size the inductor by saturation and ripple, keep D near 0.3 to 0.6, and remember light load enters discontinuous mode with higher voltage.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Switching design per GB/T 5226.1; energy to IEC 62301 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Forcing duty as the knob unlocks the loop and output runs wild; adjust feedback.
② Too small an inductor means big ripple and saturation damage.
③ Averaging duty with a meter misleads; watch the switch node on a scope.

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.

Related reading

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Electrical Knowledge Base · free self-study reference for electrical & automation engineers, 3D CAD models at MOULDL