RC snubbers for contact arcing

Opening an inductive load draws an arc that erodes contacts; the RC across the contact absorbs the energy.

1. How it works

Capacitor slows the voltage rise, resistor damps the LC ringing and limits discharge current; C≈0.5~1μF per ampere as a start.

2. Practice and pitfalls

Use film capacitors and pulse-rated resistors; RC complements - does not replace - the coil freewheel diode.

3. Snubber sizing table

LoadStarting valuesTuning signNote
Relay 24V/1A0.1μF+100ΩNo visible arcDC inductive
Contactor 220V AC0.47μF+100ΩLonger lifeWith MOV
Solenoid 24V/2A0.22~0.47μFRinging settlesFilm cap
Micro switch0.01~0.1μFNoise goneFalse triggers
SCR anodePer dv/dtNo false firingSee buffer篇
Motor brushes0.1μF+47ΩSpark ring goneBrush bypass

4. Notes

Apply the points above to RC snubbers for contact arcing; the figures are typical engineering values, so confirm them against the device datasheet and the actual design before release.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Per GB/T 14048, IEC 60384 and the corresponding IEC documents. Ratings and derating follow the device datasheet and the product design file. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Ceramic caps in snubbers
② Steady-state power rating for R
③ Skipping the coil freewheel because RC exists

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.