The speed-torque curve is the personality of a DC motor: stiff for stability, soft for muscle. The characteristic equation, four key points and the difference between series and shunt shapes settle most selection questions.
Eliminating armature current between the voltage balance and the torque expression gives n = U/(Ce·flux) minus a term proportional to torque and inversely proportional to flux squared. With nearly constant flux, shunt and separately excited machines produce a gently sloping straight line, dropping only 3 to 8 percent from no load to full load: a stiff characteristic. Series machines let flux grow with current, and the squared relationships bend the curve steeply downward: a soft characteristic. The no-load point makes the danger explicit, since the series no-load speed tends to infinity while the shunt sits 5 to 10 percent above rated.
Four points anchor the reading: ideal no-load, rated point on the nameplate, stall point where current reaches 5 to 7 times rated through Ra alone, and the working segment whose slope reveals health. Field practice uses the curve three ways: match load type, since fans and pumps pair naturally with stiff shunt drives while hoists want series torque rising at low speed; gauge speed range, since stiff curves give stable low-speed regulation; and spot faults, because a lifted curve means weakened field while a steeper slope means added armature resistance or brush contact problems.
| Point | Shunt (separately excited) | Series | Field meaning |
|---|---|---|---|
| ideal no-load | n0=U/(Ce·flux), finite | n0 tends to infinity | series must never idle |
| rated point | Me, ne from nameplate | Me, ne from nameplate | assessment baseline |
| stall point | I=U/Ra, 5~7x rated | large current and torque | current-limited starting required |
| working segment | linear, 3~8% droop | steeply bent | stiff for stability, soft for torque |
| after field weakening | n0 rises, slope steeper | complex change | usable for speed, unstable if uncontrolled |
| with series resistance | slope greatly increased | curve shifts down | starting and braking use |
Plot in per-unit values with rated point at 1.0, no load at 1.05 to 1.1 and stall current at 5 to 7, and the stiffness is visible at a glance. Re-measure the two points after overhaul and compare with history.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: See GB/T 1311 (DC machine test methods) for characteristics; ratings per GB/T 755 (IEC 60034-1). Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.