Why high-speed ADCs need a sample-and-hold circuit

A high-speed conversion needs the input frozen while it runs, and the sample-and-hold is that shutter. This page explains why it is indispensable and what its key parameters are.

1. How it works

Why an S/H is needed: a SAR and similar converters take several steps, and if the input moves meanwhile each bit is compared against a different baseline and the result is wrong. The S/H follows the input while sampling and locks the capacitor voltage for the conversion, so the input stays constant throughout. Without one, fast or multiplexed signals distort badly, worst when the input slews quickly.

2. Numbers and practice

Key parameters: aperture time is the delay from the hold command to the switch actually opening; aperture jitter makes that delay uncertain and caps high-frequency accuracy directly, an error of slope times delta-t. Leakage in the hold capacitor, op-amp settling time and feedthrough through the open switch all add error. On fast converters the jitter budget is measured in picoseconds.

3. Pitfalls and fixes

Application points: put the S/H before the ADC and synchronize the sampling pulse with the conversion. The driving op-amp must settle fast with low noise, and the hold capacitor must be low leakage. Multiplexed channels rely on the S/H to freeze each channel instant before sequential conversion. Remember that sampling-to-hold jitter converts straight into SNR loss and dominates at high input frequencies.

4. Sample-and-hold key parameters

ParameterMeaningImpact
Aperture timeOpen delayTiming offset
Aperture jitterUncertain delayHigh-frequency error
Settling timeOp-amp catching upAccuracy
LeakageCapacitor droopHold drift
FeedthroughLeak through the switchSmall glitches
Hold capacitorThe storage elementChoose low leakage

5. Notes

Fast acquisition needs an S/H with the sampling pulse synchronized to the conversion. Aperture jitter sets the ceiling on high-frequency accuracy, so the driver op-amp must settle fast and clean.

6. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Sample-and-hold per GB/T 4728 and IEC 60748 series. Always check the device datasheet and the product design file for ratings and derating.

7. Cautions

⚠️ Three common pitfalls:
① Sampling fast signals with no S/H:the input moves during conversion and the code is wrong
② Large aperture jitter:SNR at high input frequency collapses
③ Leaky hold capacitor:the held value droops and even slow signals read off

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.