Correct way to measure supply ripple and noise on a scope

Many people get wild ripple readings simply because the method is wrong. This page gives the standard posture for measuring ripple and noise with a scope.

1. How it works

Use a short ground, a ground spring or the shortest lead; a long lead is an antenna that picks up switching noise and ringing and shows a falsely large waveform. Set the probe to 10x to lessen loading, turn on 20 MHz bandwidth limit to reject pick up so the reading reflects real supply ripple not space interference. AC coupling shows only the AC content, DC coupling shows total with DC. Set vertical gain to see the spikes.

2. Practice and pitfalls

Set the time base to show a few periods, 100 Hz for mains ripple or the switching frequency for switchers. Edge trigger to steady the trace. Read peak to peak Vpp and, via measurement, RMS. Always load the supply; unloaded ripple is far smaller. Average to cut random noise, and avoid too large a probe capacitance that masks high frequency spikes.

3. Right ripple test

StepDoWrong
Groundground springlong lead ring
Bandwidthlimit 20 MHzfull BW noise
CouplingAC for rippleDC unclear
Loadreal loadno load wrong
ReadVpp and RMSsingle spike
Atten10x10x off error

4. Notes

Measure ripple with the shortest ground spring, 20 MHz limit on, AC coupling, real load and read Vpp and RMS. Avoid long lead ringing and space EMI ghosts, set probe attenuation right, and do not use a meter for high frequency ripple.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Ripple test per GB/T 5226.1; scope use to GB/T 19862 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Long ground lead reads ringing and calls it ripple; use a ground spring.
② No 20 MHz limit takes space EMI as supply ripple.
③ Testing unloaded misjudges pass because ripple is far smaller.