Many people get wild ripple readings simply because the method is wrong. This page gives the standard posture for measuring ripple and noise with a scope.
Use a short ground, a ground spring or the shortest lead; a long lead is an antenna that picks up switching noise and ringing and shows a falsely large waveform. Set the probe to 10x to lessen loading, turn on 20 MHz bandwidth limit to reject pick up so the reading reflects real supply ripple not space interference. AC coupling shows only the AC content, DC coupling shows total with DC. Set vertical gain to see the spikes.
Set the time base to show a few periods, 100 Hz for mains ripple or the switching frequency for switchers. Edge trigger to steady the trace. Read peak to peak Vpp and, via measurement, RMS. Always load the supply; unloaded ripple is far smaller. Average to cut random noise, and avoid too large a probe capacitance that masks high frequency spikes.
| Step | Do | Wrong |
|---|---|---|
| Ground | ground spring | long lead ring |
| Bandwidth | limit 20 MHz | full BW noise |
| Coupling | AC for ripple | DC unclear |
| Load | real load | no load wrong |
| Read | Vpp and RMS | single spike |
| Atten | 10x | 10x off error |
Measure ripple with the shortest ground spring, 20 MHz limit on, AC coupling, real load and read Vpp and RMS. Avoid long lead ringing and space EMI ghosts, set probe attenuation right, and do not use a meter for high frequency ripple.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Ripple test per GB/T 5226.1; scope use to GB/T 19862 and IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.