Why rectified DC can read too high

Many people see a rectified voltage above nominal and assume a fault, but often it is the no load peak effect or a regulation issue. This page lists the causes one by one and how to tell them apart.

1. How it works

With a capacitor input filter the unloaded cap charges to the root two peak of the AC, so 220 V rectified reads about 310 V open and falls to about 270 V under load. That is the capacitor, not a fault. Only if it stays high under load do you look at regulation. Beginners often treat the no load high as a fault and fiddle the pot, ruining the supply.

2. Practice and pitfalls

If it stays high under load, check the sense divider: a larger top resistor or smaller bottom one lowers the sense point so the loop thinks output is low and eases off, pushing real output up. A drifting reference like TL431 also climbs, and a worn pot or aged opto coupler with lower CTR makes the primary give too much duty.

3. High output voltage causes

SymptomPossible causeCheck or fix
High open, ok loadcapacitor peaknormal
High under loadsense resistorprobe divider
Wont setpot wornreplace pot
Drifts upref failedswap TL431
Opto agedCTR downswap opto
Mains highinput overcheck line

4. Notes

First load it: if it falls it is normal peak effect; if not, check sense resistors, reference, opto and pot. Confirm the meter is reliable and on the right range before touching the circuit.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Power regulation and test per GB/T 5226.1; reference parts to IEC 60204-1 and GB/T 12350. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Treating no load high as a fault and adjusting ruins the pot or divider.
② A normal meter on a switching supply reads induced spikes as high voltage; use true RMS.
③ Swapping only the bridge ignores regulation; the fault is in feedback.

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.