The nameplate lists rated starting and maximum torque often mixed up; they govern different conditions and both matter for selection and start troubleshooting. This page separates the three.
Rated torque T_N is the continuous torque at rated voltage and rated speed corresponding to rated power T_N equals 9550 P_N over n_N. Starting torque T_st is the torque at zero speed at start. Maximum torque T_max is the peak the motor can develop usually near synchronous speed. They are three distinct operating points.
Typical async motor: T_st about 1.5 to 2.5 times T_N and T_max about 2 to 3 times T_N. At start the load must be below T_st or it will not move; during acceleration the speed passes near T_max so load peak below T_max avoids stall. Pit: selecting only by rated torque but starting torque too low for heavy belt or compressor; pit: load inertia so high that though rated is fine the acceleration peak exceeds T_max and stalls.
| Torque | Condition | Multiple of rated | Meaning |
|---|---|---|---|
| Rated T_N | rated steady | 1.0 | steady base |
| Start T_st | n=0 | 1.5 to 2.5 | can it start |
| Max T_max | near sync | 2 to 3 | stall limit |
| Load start | below T_st | need margin | else no move |
| Load peak | below T_max | avoid stall | else crash |
| Pit | rated only | no start | heavy fail |
Rated T_N is the steady base torque equal 9550 P over n; starting T_st about 1.5 to 2.5 times governs whether it starts; maximum T_max about 2 to 3 times is the stall limit. Check both against load start and peak not just rated.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Rotating machine torque see IEC 60034-1 and electrical safety see GB/T 5226.1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.