Wrong DIP settings on the driver mean weak torque or a burnt motor. This page details how to pick the current range and microstep and match them to the motor rating and controller pulse equivalent.
Set output current to motor rated or slightly below, say 2.8 A for a 2.8 A motor, lower if heat is high. Too low loses steps, too high overheats the motor, demagnetises the magnet or trips the driver; rule is enough but not over. Use the idle half-current feature to drop to 30 to 50 percent when stationary, saving heat while keeping holding torque.
Microstep count sets pulses per revolution and smoothness; larger means finer resolution and smoother running but lower per-microstep torque and stricter driver linearity, commonly 1/8 to 1/32. It must match the controller pulse equivalent: pulses per rev equals 200 times microstep for a 1.8-degree motor, and pulse equivalent equals lead divided by pulses per rev. Wrong microstep makes real travel disagree with commands. After setting, send a known pulse count and measure rotation; 3200 pulses at 1/8 microstep? note 1/16 gives 3200 per rev for 1.8-degree, deviation means mis-setting. Also keep supply within spec and pick decay mode by motor inductance.
| Item | Setting | Basis | If wrong |
|---|---|---|---|
| Current | = rated | Nameplate | Weak or hot |
| Microstep | 8~32 | Precision | Equivalence off |
| Idle half current | On | Less heat | Hot |
| Decay mode | Per inductance | Motor | Rough motion |
| Supply voltage | Within spec | Driver | Damage |
Set driver current to the motor rating, enough but no more: too low loses steps, too high overheats and demagnetises. Pick microstep 1/8~1/32; it sets pulses per revolution and smoothness and must agree with the controller pulse equivalence (pulses per rev = 200 x microstep). Enable idle half-current to cut heat. Verify after setting: send 3200 pulses (1.8 deg at 1/16) and the shaft must turn exactly one revolution; any offset means a wrong setting.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Stepper drives per applicable standards; electrical safety: GB/T 5226.1 / IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.