A stepper jitters at low speed because of low-frequency oscillation and resonance. This page explains why a certain speed band resonates and the suppression means, and how to tune it out on site.
The stepper plus load is a spring-inertia system with a natural resonance, often around 100 to 200 pps or some mid-low speed; when the drive frequency nears it the rotor oscillation amplifies into shake, noise and lost steps, and square-wave current switching also excites low-frequency oscillation. This is typical open-loop behaviour.
The most effective cure is microstepping, turning square waves into sinusoidal microsteps that blunt the excitation harmonics and smooth the resonance peak. Other means: avoid the resonance band by speeding through it in the motion plan; add mechanical damping such as a flywheel, viscous damper or rubber mounts to shift the natural frequency; raise drive voltage and use chopper constant current to steady current; and never dwell in the band. On site, find the shaking frequency by ear or vibration, switch to 1/8 microstep or above which usually removes it, else avoid the band and add damping. Resonance not only shakes but causes lost steps and bearing wear if run there long; closed-loop steppers suppress it by feedback.
| Method | Mechanism | Effect | Action |
|---|---|---|---|
| Microstepping | Sinusoidal microsteps | Best | Set 1/8 or finer |
| Skip the band | Avoid the frequency | Effective | Plan moves |
| Mechanical damping | Absorbs vibration | Helper | Add dampers |
| Raise drive voltage | Stiffer current loop | Helps | Adjust driver |
| Closed loop | Feedback damps | Strongest | Add encoder |
A stepper resonates at low and certain mid speeds because the drive frequency lands near a system natural frequency and the square-wave switching excites it, showing up as buzz, vibration and lost steps. The strongest fix is microstepping, whose sinusoidal microsteps flatten the resonance peak. Also: plan speed profiles to jump over the resonant band, add mechanical damping, raise drive voltage for a stiffer current loop, or go closed loop. Living in the resonance band loses steps and grinds the bearings, so fix it.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Steppers per applicable standards; electrical safety: GB/T 5226.1 / IEC 60204-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.