In rectifier filters the electrolytic cap fails most often by bulging, and the root is usually excess ripple current, heat or overvoltage. This page explains the failure mechanism and how to extend life.
An aluminium electrolytic works on electrolyte; ripple current heats the ESR, raising internal temperature so the electrolyte slowly dries and gas builds, pushing the safety vent out as a bulge. Every 10 C rise halves life, so an 85 C rated part in a 60 C cabinet may last only a year or two. Exceeding ripple current is the direct killer, and near rated voltage also ages it fast.
Derating is the rule: voltage at 1.5 times peak is a floor, twice is safer for critical gear; ripple current rating must beat actual with margin; pick 105 C grade for double the life of 85 C; keep capacity margin. Parallel caps share ripple and cut ESR, and a small ceramic covers high frequency.
| Factor | Effect | Fix |
|---|---|---|
| Ripple over | heat spikes | big margin |
| High temp | life halves | 105 C |
| Voltage high | ages fast | 1.5 to 2 |
| High ESR | load ripple | low ESR par |
| Crowded | mutual bake | airflow |
| Reverse | explode | watch polarity |
Bulging starts with heat and ripple current, so derate, use high temp low ESR parts, parallel to share and leave airflow. When one bulges, swap to the same high temp type and fix the cause, not just the can.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Capacitor life and selection per GB/T 2693; equipment safety to GB/T 5226.1 and IEC 60384. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.