Why electrolytic caps bulge in rectifier filters

In rectifier filters the electrolytic cap fails most often by bulging, and the root is usually excess ripple current, heat or overvoltage. This page explains the failure mechanism and how to extend life.

1. How it works

An aluminium electrolytic works on electrolyte; ripple current heats the ESR, raising internal temperature so the electrolyte slowly dries and gas builds, pushing the safety vent out as a bulge. Every 10 C rise halves life, so an 85 C rated part in a 60 C cabinet may last only a year or two. Exceeding ripple current is the direct killer, and near rated voltage also ages it fast.

2. Practice and pitfalls

Derating is the rule: voltage at 1.5 times peak is a floor, twice is safer for critical gear; ripple current rating must beat actual with margin; pick 105 C grade for double the life of 85 C; keep capacity margin. Parallel caps share ripple and cut ESR, and a small ceramic covers high frequency.

3. Cap failure and longer life

FactorEffectFix
Ripple overheat spikesbig margin
High templife halves105 C
Voltage highages fast1.5 to 2
High ESRload ripplelow ESR par
Crowdedmutual bakeairflow
Reverseexplodewatch polarity

4. Notes

Bulging starts with heat and ripple current, so derate, use high temp low ESR parts, parallel to share and leave airflow. When one bulges, swap to the same high temp type and fix the cause, not just the can.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Capacitor life and selection per GB/T 2693; equipment safety to GB/T 5226.1 and IEC 60384. Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Running over ripple rating spikes heat and bulges fast; pick large margin.
② Swapping 85 C for 105 C in a hot cabinet halves life again and again.
③ Only changing the can ignores the heat cause and it bulges again.

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.