A single-phase motor left to itself will not begin to turn; that is a built-in limitation. This page explains the pulsating field, why a phase shift is needed, and why it can keep running once spinning.
A single winding fed with AC produces a pulsating field whose axis stays fixed while its magnitude swings; it pulls the rotor back and forth with zero net torque, so at standstill the start torque is zero. That is the root difference from three-phase, where phase displacement naturally creates a rotating field. Without a second element the single-phase machine is just a non-rotating electromagnet.
To start, a second winding is placed 90 electrical degrees away and its current is shifted in phase by a capacitor or resistor, so the combination approximates a rotating field and gives a definite direction. Once spinning, the pulsating field sustains torque through rotor-induced current, so the motor can run without the auxiliary winding. That is why capacitor-run and shaded-pole constructions work: start by phase split, run by single winding.
| Item | Single phase | Three phase | Reason |
|---|---|---|---|
| Standstill torque | 0 | Present | Field |
| Starting method | Split phase | Natural | Phase shift |
| Auxiliary winding | Required | None | Construction |
| Once running | Self-sustaining | Self-sustaining | Induction |
| Direction | Set by auxiliary | Set by sequence | Defined |
Zero standstill torque is the birth defect of a pulsating single-phase field; only an auxiliary winding with capacitor or resistor phase shift creates a starting torque. Once spinning, the single winding sustains itself fine. Understanding this explains why every single-phase motor needs a start winding or shaded poles in the first place.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Single-phase motors: GB/T 12350; rotating machine principles: GB/T 755 / IEC 60034-1. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.