Capacitor units, value codes and the E6 series - read any marking in seconds

Capacitors span 12 orders of magnitude: 1F=10⁶µF, 1µF=1000nF, 1nF=1000pF. Power capacitors live in µF~mF, signal work in nF~pF.

1. How it works

Three-digit codes: first two digits are significant, the third counts zeros in pF - 104=100000pF=0.1µF, 105=1µF, 4R7=4.7pF; suffix J/K/M gives tolerance ±5/10/20%.

2. Practice and pitfalls

Nominal values follow the E6 series 1.0/1.5/2.2/3.3/4.7/6.8 per decade; pick the nearest series value instead of inventing 5µF or 200pF.

3. Value code quick table

MarkingMeaningResultTypical use
10410×10⁴ pF0.1µF=100nFDecoupling, bypass
22422×10⁴ pF0.22µFFiltering, coupling
10510×10⁵ pF1µFSupply filtering
47247×10² pF4.7nFTiming, snubber
4R7R = decimal point4.7pFHF resonance
4.7µF/50VDirect marking4.7µF, 50V ratedElectrolytic, read as printed
6J6pF, ±5%6pF J-gradeSmall HF values

4. Notes

Read in fixed order: decimal point (direct value), three-digit code (convert from pF), then tolerance letter and voltage rating. One chain to remember: 1µF=1000nF=10⁶pF.

5. References

The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Marking codes per GB/T 2693; preferred number series per GB/T 2471 (IEC 60063). Always check the device datasheet and the product design file for ratings and derating.

6. Cautions

⚠️ Three common pitfalls:
① Reading 104 as 104pF:The third digit counts zeros: 104 is 0.1µF, six orders off
② Converting between units by 100×:Adjacent steps µF-nF-pF are 1000×, not 100×
③ Specifying values outside E6:Series values only exist as 1.0/1.5/2.2/3.3/4.7/6.8 decades - redesign or parallel two caps

Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.