Large capacitors and cold filaments draw an inrush many times the running current and blow fuses at switch-on. This page sizes the RC network and the bypass relay to keep the peak near two to three times the steady value.
Limit the peak with a series resistor where I peak equals supply over R. To cap a 220 volt rail at 5 ampere, pick R near 47 ohm and rate it for the transient power. Add a capacitor across the load sized by C at least I times t over delta U, so a 0.5 ampere load held for 10 millisecond within a 10 percent dip needs about 330 microfarad.
Finish with a relay that shorts the resistor once the capacitor is charged, otherwise the resistor burns and wastes power. Switch the relay at roughly 90 percent of the final voltage, about 2.3 tau, using a timer or comparator set to three to five tau. An NTC thermistor is simpler but must cool between cycles or it loses its limiting effect.
| Part | Role | Typical |
|---|---|---|
| Series R | limit peak current | 47 ohm 5 W |
| Capacitor C | absorb spike | 330 uF 400 V |
| Bypass relay | short the R | 12 V DC |
| NTC | cold limit, hot low | 10 to 1 ohm |
| Timer | timed short | 3 to 5 tau |
| Protection | stop R heat | thermal switch |
Use soft-start for filaments, large capacitors and inverter front ends. Size the relay contact at twice the load current and rate the resistor by transient I squared R, not the steady state, or it fails on the first switch-on.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: Low-voltage switchgear follows GB/T 14048 and IEC 60204 for safety. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.