Fix a fixed order: identify the quantity, set jack and range, then probe. Most accidents are order violations.
Voltage: parallel, start high. Current: series, de-energize first. Resistance: power off, discharge capacitors, lift one leg.
Ten classic mistakes include leaving leads in the current jacks, measuring resistance live, and switching ranges under load.
| Mistake | Consequence | Prevention |
|---|---|---|
| Leads in A jacks, measure volts | Shunt blown | Check jacks first |
| Voltage mode to read current | Meaningless | Series only |
| Ω mode on live circuit | Meter damaged | De-energize |
| Current jacks across supply | Short arc | Series insertion |
| Range change under load | Switch damage | Remove probes |
| Capacitor not discharged | Front-end damaged | Discharge first |
| In-circuit resistance | Parallel paths | Lift one leg |
| Range low to high | Overload | High to low |
| Leads left in A jacks | Next user shorts | Return to VΩ |
| Diode mode on SCR | Wrong verdict | Follow datasheet |
Print 'power off - discharge - lift - select' on the meter case and keep the same order as a team habit.
The quantities and component characteristics discussed here follow current national standards and the corresponding IEC documents: DMM safety and accuracy per GB/T 13978; live-measurement safety per electrical safety codes. Always check the device datasheet and the product design file for ratings and derating.
Locate the issue with the approach above, then confirm with measurements; safety-related circuits must follow the standards and manufacturer requirements.